Okay, I have determined that the blower motor transistor is fubared! Motor only operates on high speed when the relay kicks in. Does anyone know where i can get a replacement without pulling from a salvage yard? Maybe a digikey part number :P.

Thanks
-Andy
Reply
Old Dec 12, 2008 | 03:57 PM
  #2  
nonameuser's Avatar
Thread Starter
Junior Member
Tenured Member 15 Years
 
Joined: Oct 2005
Posts: 19
Likes: 0
From: Charleston SC
Thanks for your help everyone. bah, jk. just in case someone else ever has this problem...

P/N MJ11016GOS-ND
Desc trans darl npn 30A 120V T03
$3.72 + ship

Just incase anyone stumbles on this thread looking for part numbers, im going to include these other P/N from digikey. The following parts are the 2 types of replacement relays needed for the wiper switch fix. There are several how-tos on the fix so i wont go into it here. But i remember having trouble finding the right relays. so here you go..

P/N 255-1240-ND
Desc relay auto mini spdt 15a 12vdc
$1.42 + ship

P/N Z950-ND
Desc relay pc mn 8A spst-no/nc 12vdc
$5.73 + ship

Last edited by nonameuser; Dec 12, 2008 at 04:13 PM. Reason: Decided to add other part numbers
Reply
Old Dec 14, 2008 | 01:05 AM
  #3  
nonameuser's Avatar
Thread Starter
Junior Member
Tenured Member 15 Years
 
Joined: Oct 2005
Posts: 19
Likes: 0
From: Charleston SC
made a write up

https://www.rx7club.com/showthread.p...89#post8798189
Reply
Old Dec 14, 2008 | 05:08 PM
  #4  
eage8's Avatar
1308ccs of awesome
Tenured Member: 20 Years
iTrader: (9)
 
Joined: Sep 2003
Posts: 6,189
Likes: 18
From: Woodbine, MD
Originally Posted by nonameuser
Okay, I have determined that the blower motor transistor is fubared! Motor only operates on high speed when the relay kicks in. Does anyone know where i can get a replacement without pulling from a salvage yard? Maybe a digikey part number :P.

Thanks
-Andy
awesome write up on your other thread.

mine recently started to not work at all, but I can hear the relay clicking. do you think it's the same thing? Recently it worked one morning on the super high setting, and then stopped again.

-Mike
Reply
Old Dec 14, 2008 | 07:08 PM
  #5  
deletedcold's Avatar
Just Cruisin'
Tenured Member: 15 Years
iTrader: (1)
 
Joined: Oct 2005
Posts: 119
Likes: 1
From: Raleigh NC
+1 on the write up. useful info there
Reply
Old Dec 14, 2008 | 08:13 PM
  #6  
Osirus9's Avatar
Jackstand Drifter
Tenured Member 05 Years
iTrader: (10)
 
Joined: Dec 2006
Posts: 1,065
Likes: 1
From: Chicago, IL
Originally Posted by eage8
awesome write up on your other thread.

mine recently started to not work at all, but I can hear the relay clicking. do you think it's the same thing? Recently it worked one morning on the super high setting, and then stopped again.

-Mike
i have the exact same problem. EXACTLY. I've been through 3 logicons as well, could this be the true culprit?
Reply
Old Dec 15, 2008 | 04:55 AM
  #7  
nonameuser's Avatar
Thread Starter
Junior Member
Tenured Member 15 Years
 
Joined: Oct 2005
Posts: 19
Likes: 0
From: Charleston SC
The motor is controlled by several factors... There are 2 relays attached to the blower assembly. The main one with 5 wires is the main power relay. If this relay is bad then the fan wont work on any setting. The other relay turns on when you turn up the fan speed to max. If your fan speed control works, but just doesnt seem to blow like it should when on high, check this relay. When the main relay is on and the 2nd is off (any setting but high or off), the transistor controls the fan speed...

hope this helps..
Reply
Old Dec 15, 2008 | 05:04 AM
  #8  
Osirus9's Avatar
Jackstand Drifter
Tenured Member 05 Years
iTrader: (10)
 
Joined: Dec 2006
Posts: 1,065
Likes: 1
From: Chicago, IL
well I have new (ish) relays coming in the mail, and this transistor, so my blower better work after that.

also, i went on digikey's site and they only ship to the UK apparently, so I got mine from here: http://www.newark.com/
Reply
Old Dec 15, 2008 | 05:19 AM
  #9  
nonameuser's Avatar
Thread Starter
Junior Member
Tenured Member 15 Years
 
Joined: Oct 2005
Posts: 19
Likes: 0
From: Charleston SC
Originally Posted by Osirus9
well I have new (ish) relays coming in the mail, and this transistor, so my blower better work after that.

also, i went on digikey's site and they only ship to the UK apparently, so I got mine from here: http://www.newark.com/
Digikeys site did that to me too... They do however ship to the US. They must be having issues.
Reply
Old Dec 15, 2008 | 08:08 AM
  #10  
lnbrown5981's Avatar
Just take the blue pill..
Tenured Member 20 Years
 
Joined: May 2003
Posts: 558
Likes: 1
From: EU
Do you have the part number for the second blower motor relay? I tried everything to get my fan to blow out stronger, sealing the ducts, replacing logicon, and even replacing the blower motor itself, all to no avail. The fan does go from low to high, but just doesn't blow out very strong on the highest setting. Maybe the second relay is the culprit.
Reply
Old Dec 17, 2010 | 10:18 AM
  #11  
trickdrift's Avatar
Junior Member
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 20
Likes: 0
From: Ames
Similar Issue

So originally my blower motor did not work and its brand new. So I resodered the connections on the cpu circuit board. Then I got the blower to work but only on max speed. So then I checked out the power transistor and it seemed fine. But I still resodered the connects around it and repairs mouse chewed wires. Then hooked it back up again and it worked! It worked on max but when I adjusted the fan speed it slowed down a little. But not as much as it should be when the fan was set to low. I do have a new logicon installed so I figured it can't be that. Unless what ever the small blackbox which is attached to the logicon is bad. Anyway I was excited for about 5 minutes and then the blower motor stopped working completely. Please help I would like to have heat and a/c in my car.
Reply
Old Dec 17, 2010 | 06:23 PM
  #12  
jjwalker's Avatar
MECP Certified Installer
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 3,176
Likes: 3
From: Mesquite, TX-DFW
My blower motor won't even work in high speed. Both relays are clicking and doing their thing.

That transistor wouldn't be the issue would it?

All fuses are good. I haven't gone any farther than just checking those due to it being cold outside.
Reply
Old Dec 17, 2010 | 06:49 PM
  #13  
clokker's Avatar
Cake or Death?
Tenured Member 10 Years
iTrader: (2)
 
Joined: Jan 2007
Posts: 10,249
Likes: 64
From: Mile High
The transistor isn't part of the high speed loop, so maybe the motor itself is bad.
Reply
Old Dec 17, 2010 | 06:52 PM
  #14  
jjwalker's Avatar
MECP Certified Installer
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 3,176
Likes: 3
From: Mesquite, TX-DFW
Originally Posted by clokker
The transistor isn't part of the high speed loop, so maybe the motor itself is bad.
Doubtful but possible.

It worked one day and the next it didnt.

I also cannot engage my AC clutch.
Reply
Old Dec 17, 2010 | 07:05 PM
  #15  
satch's Avatar
Moderator
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Jun 2005
Posts: 11,738
Likes: 16
From: tulsa,ok.
Originally Posted by jjwalker
Doubtful but possible.

It worked one day and the next it didnt.

I also cannot engage my AC clutch.
If the coolant level is low the pressure sensor that measures coolant pressure would prevent the clutch from engaging I think.
Reply
Old Dec 17, 2010 | 09:26 PM
  #16  
jjwalker's Avatar
MECP Certified Installer
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 3,176
Likes: 3
From: Mesquite, TX-DFW
Originally Posted by satch
If the coolant level is low the pressure sensor that measures coolant pressure would prevent the clutch from engaging I think.
My AC doesnt work because it is clogged, but it had plenty of pressure.

I am thinking that it is a freak power issue.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
sYnth.
Build Threads
0
Aug 19, 2015 06:27 PM
rexhvn
3rd Generation Specific (1993-2002)
0
Aug 19, 2015 02:59 AM
andyvideopro
General Rotary Tech Support
2
Aug 11, 2015 09:16 PM




All times are GMT -5. The time now is 03:46 AM.