Pressurized gas tank - what gives?

My car runs fine, but when I fill up the tank hisses and I can see distortion on the grond from the vapor. That's why I think it's pressurized rather than under vacuum. What's up?
Reply
Old Oct 1, 2003 | 06:18 PM
  #2  
Critoris's Avatar
Thread Starter
Senior Member
Tenured Member 05 Years
 
Joined: Mar 2003
Posts: 264
Likes: 0
From: Da ATL
okay, so i filled up today and it's definitely pressurized - not a vacuum. any idea what would cause this?
Reply
Old Oct 1, 2003 | 06:21 PM
  #3  
10sec rx7's Avatar
Rotary Enthusiast
Tenured Member 20 Years
 
Joined: Mar 2001
Posts: 1,353
Likes: 9
From: Sydney, Australia
blocked breather,

if get under the car inbetween the diff and fuel tank on the floor pan you will see a valve and a line that wiggles its way around the floor pan, this is the breather, make sure it isnt blocked or crushed, this also goes to the charcol canaster,

Dale
Reply
Old Oct 2, 2003 | 04:16 AM
  #4  
Critoris's Avatar
Thread Starter
Senior Member
Tenured Member 05 Years
 
Joined: Mar 2003
Posts: 264
Likes: 0
From: Da ATL
okay, so is it an emissions thing that i can get from autozone, or what?
Reply
Old Oct 2, 2003 | 10:03 AM
  #5  
bliffle's Avatar
Rotary Freak
Tenured Member 10 Years
 
Joined: Sep 2002
Posts: 2,815
Likes: 0
From: SF BayArea
I thought they all did that: some modern emissions control thing. Shouldn't it hiss? I can't think of a car I've owned in the last 20 years that hasn't done it.

B
Reply
Old Oct 2, 2003 | 12:25 PM
  #6  
Rx7carl's Avatar
Airflow is my life
Tenured Member 10 Years
 
Joined: Aug 2002
Posts: 6,736
Likes: 2
From: Orlando, Fl
Read the manual. It should hold a small amount of positive or negative pressure before venting it to equalize with atmosphere. If the vent valve 10sec mentions fails, or the charcol cannister gets clogged, then itll allow excessive pos and/or neg pressure to build up.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
barkz
Power FC Forum
37
Nov 21, 2020 09:34 AM
stickmantijuana
3rd Generation Specific (1993-2002)
13
Jan 9, 2018 11:19 AM
ZacMan
Build Threads
4
Sep 19, 2015 09:20 PM
ZaqAtaq
New Member RX-7 Technical
2
Sep 5, 2015 08:57 PM
gabescanlon
3rd Generation Specific (1993-2002)
7
Sep 5, 2015 12:09 AM




All times are GMT -5. The time now is 09:09 PM.