Single Turbo RX-7's Questions about all aspects of single turbo setups.

what to do with leftover connections under manifold

Thread Tools
 
Search this Thread
 
Old Apr 29, 2003 | 10:42 PM
  #1  
Mikey's Avatar
Thread Starter
Senior Member
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 310
Likes: 0
From: Carl Junction, MO
what to do with leftover connections under manifold

what did you guys do with the leftover rats nest connectors? just leave them?...they look bad just sitting there. i was wondering if anybody got creative.
Reply
Old Apr 30, 2003 | 08:15 AM
  #2  
TYSON's Avatar
WTF is wrong with it now?
Tenured Member 10 Years
 
Joined: Oct 2001
Posts: 1,492
Likes: 0
From: London, ON
Chop Chop

What ECU do you have first?
Reply
Old Apr 30, 2003 | 11:38 AM
  #3  
Mikey's Avatar
Thread Starter
Senior Member
Tenured Member 10 Years
 
Joined: Feb 2001
Posts: 310
Likes: 0
From: Carl Junction, MO
haha that is what i was thinking. i have the power fc...so that means i can just cut them out right? since the computer wont throw codes :-D
Reply
Old Apr 30, 2003 | 01:29 PM
  #4  
TYSON's Avatar
WTF is wrong with it now?
Tenured Member 10 Years
 
Joined: Oct 2001
Posts: 1,492
Likes: 0
From: London, ON
Yup. Power FC don't care.
Reply
Old Apr 30, 2003 | 09:58 PM
  #5  
t04rx7's Avatar
Full Member
Tenured Member 05 Years
 
Joined: Sep 2002
Posts: 52
Likes: 0
From: Atlanta, GA
yeah, you can just cut them, but *make sure* you disconnect the battery first. I think I may have fried my PFC this way.. oops, there goes $1000..

Last edited by t04rx7; Apr 30, 2003 at 10:02 PM.
Reply
Old May 1, 2003 | 11:02 AM
  #6  
c00lduke's Avatar
Rotary Freak
Tenured Member 20 Years
 
Joined: Jan 2002
Posts: 2,360
Likes: 0
From: Overland Park, KS
Do you have to tape off the conenctions after you cut them? And if you do, should you make sure none of the cut wires touch eachother?
Reply
Old May 1, 2003 | 12:06 PM
  #7  
Trav's Avatar
Rotary Enthusiast
Tenured Member 10 Years
 
Joined: Aug 2002
Posts: 1,273
Likes: 0
From: Kansas
Originally posted by c00lduke
should you make sure none of the cut wires touch eachother?

ALWAYS.
Reply
Old May 1, 2003 | 09:37 PM
  #8  
Northwest FD3S's Avatar
Rich Hoe
Tenured Member 05 Years
 
Joined: Mar 2002
Posts: 352
Likes: 0
From: Coquitlam BC
Instead of tape use a little heat shrink tubing and then fill the end with a little crazy glue.