Single Turbo RX-7's Questions about all aspects of single turbo setups.

rx6 ic piping size

Thread Tools
 
Search this Thread
 
Old 03-16-03, 09:16 PM
  #1  
Rotary Enthusiast

Thread Starter
 
2manytickets's Avatar
 
Join Date: Apr 2002
Location: pembroke, ma
Posts: 990
Likes: 0
Received 0 Likes on 0 Posts
rx6 ic piping size

are you guys with the rx6 using the piping that came with the kit, it seems a little small, let me know
Old 03-17-03, 04:18 AM
  #2  
WWFSMD

 
maxcooper's Avatar
 
Join Date: Jun 2001
Location: SoCal
Posts: 5,035
Likes: 0
Received 4 Likes on 4 Posts
The compressor outlet is 2.5", which I think is the same size as the piping. I only use the cast elbow and some of the couplers, but 2.5" is a reasonable size for this stuff, I think. I did a calc once and found it to be okay using the rule of thumb from Corky Bell's book. I think it was 350 ft/sec velocity in the pipe or something, and at 600 CFM (high estimate) 2.5" was under that velocity. I'm too lazy or I would do the calc again.

That is not to say that bigger might not be better, but just that 2.5" is not grossly undersized for this application.

-Max