New Member RX-7 Technical Post your first technical questions here, in an easy flame free environment, before jumping into the main technical sections.

disable air pump 3rd gen RX7

Old May 10, 2010 | 02:41 PM
  #1  
onesus's Avatar
Thread Starter
Junior Member
 
Joined: May 2010
Posts: 20
Likes: 0
From: Germany, Europe
disable air pump 3rd gen RX7

want to disable the air pump for correct AFR-logging with datalogit and wideband. What is the easiest way to do that? What exactly do I have to do? Is it enought to disconnect the air pump connector? Or do I have to remove the air pump relay?

Chris
Reply
Old May 11, 2010 | 06:28 PM
  #2  
gracer7-rx7's Avatar
needs more track time
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (16)
 
Joined: Mar 2006
Posts: 9,767
Likes: 797
From: Bay Area CA
Easiest way is to unplug the electrical connection to the airpump. The plug is right above the airpump so you can't miss it. Then uncheck the O2 feedback checkbox in the PFC settings using the datalogit and you are good to go for logging. I believe the airpump is not active after 3-4,000 RPM fyi.