Microtech Area is for discussing Microtech systems

Microtech LT 8 from FC to FD

Old 03-11-06, 08:43 PM
  #1  
Rotary Freak
Thread Starter
iTrader: (5)
 
Johny zoom's Avatar
 
Join Date: Jun 2002
Location: Va
Posts: 1,549
Likes: 0
Received 0 Likes on 0 Posts
LT 8 from FC to FD

I got a deal on an engine from a FD Right now Im running an FC with LT8 Can I keep same the microtech. How do I wire the CAS the Fd has a trigger wheel and the fc has a CAS?


Thanks
Johny
Johny zoom is offline  
Old 03-28-06, 09:19 PM
  #2  
Senior Member
iTrader: (2)
 
Join Date: Mar 2002
Location: Trinidad, West Indies
Posts: 278
Likes: 0
Received 1 Like on 1 Post
Dude, u may have to send back the ECU to get re-configured for use with the series 6 triggers....go to their web site ...
spanner is offline  
Old 04-06-06, 09:56 AM
  #3  
Senior Member
5 Year Member
iTrader: (3)
 
Join Date: Feb 2006
Location: Jacksonville Florida
Posts: 308
Likes: 0
Received 0 Likes on 0 Posts
I'm in a similar situation. Told by Tim at Microtech that the unit needs to be sent back to them and for $350 AU they will reconfigure, +$25 shipping each way. If you find out sometihing else, please let me know.
Madee is offline  
Old 05-05-06, 01:42 PM
  #4  
Senior Member
10 Year Member
iTrader: (8)
 
20B3rdgen's Avatar
 
Join Date: Aug 2004
Location: Land O Lakes, FL
Posts: 385
Likes: 0
Received 0 Likes on 0 Posts
I dont know why they have to go back, The 2nd and 3rd gens both have HALL (magnetic) type Crank Angle Sensor, just in different locations. They should be about to just reprogram it.
20B3rdgen is offline  
Old 05-05-06, 05:18 PM
  #5  
Senior Member
10 Year Member
iTrader: (8)
 
20B3rdgen's Avatar
 
Join Date: Aug 2004
Location: Land O Lakes, FL
Posts: 385
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by 20B3rdgen
I dont know why they have to go back, The 2nd and 3rd gens both have HALL (magnetic) type Crank Angle Sensor, just in different locations. They should be about to just reprogram it.
I incorrectly stated that "both have HALL (magnetic)" I meant to state that they both have Reluctor (magnetic) and not Hall(optical).
20B3rdgen is offline  

Thread Tools
Search this Thread

Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

© 2019 MH Sub I, LLC dba Internet Brands

We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.
 
  • Ask a Question
    Get answers from community experts
Question Title:
Description:
Your question will be posted in: