Microtech Area is for discussing Microtech systems

Microtech Cooling fan issue

Thread Tools
 
Search this Thread
 
Old Jun 8, 2012 | 09:09 PM
  #1  
stickmantijuana's Avatar
Thread Starter
Rotary Enthusiast
Tenured Member 15 Years
iTrader: (1)
 
Joined: Dec 2006
Posts: 927
Likes: 11
From: east
Cooling fan issue

I have Microtech LT16 controlling 20B motor.

Right now, one of the issues is cooling fans not turning on. I narrowed this down to the signal wire going to the cooling fan relay. When I manually ground the relay coil, fans do turn on, but when I connect it to Aux#2 (WHITE/RED) wire which should control the fan relay on LT-16, fan does not turn on. I have continuity of the wire back to the LT16 from the relay.. There's no voltage on the white/red wire. Any suggestions?
Reply
Old Jun 9, 2012 | 04:15 AM
  #2  
mattmarrx3's Avatar
Full Member
Tenured Member 05 Years
 
Joined: Apr 2005
Posts: 115
Likes: 0
From: nz
whats the fan temp set on might not be set
Reply
Old Jun 9, 2012 | 05:08 AM
  #3  
stickmantijuana's Avatar
Thread Starter
Rotary Enthusiast
Tenured Member 15 Years
iTrader: (1)
 
Joined: Dec 2006
Posts: 927
Likes: 11
From: east
I don't have the microtech serial laptop adapter. Is there any way for me to check this without it?
Reply
Old Jun 10, 2012 | 10:24 AM
  #4  
Aaron Cake's Avatar
Engine, Not Motor
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Feb 2001
Posts: 29,798
Likes: 128
From: London, Ontario, Canada
The output is ground switched, you won't find any voltage on it. One side of the relay coil connects to 12V, the other side to the Microtech.