Testing one way valves

Is there a way to test one way check valves? For example the one that runs from the turbo pre-control solenoid to the vacuum chamber. Would the method for testing this check valve apply to all check valves?
Reply
Old Aug 15, 2007 | 08:08 PM
  #2  
cptpain's Avatar
Torqueless Wonder
Tenured Member 15 Years
iTrader: (1)
 
Joined: Oct 2004
Posts: 2,020
Likes: 3
From: Texas
you take them out and blow into the direction the arrow points.... then the other side.... if you feel your breath come out on the opposite side of the arrow then they are bad

am i right?
Reply
Old Aug 15, 2007 | 09:22 PM
  #3  
Stix37867's Avatar
Got Rotors?
Tenured Member: 20 Years
iTrader: (1)
 
Joined: Aug 2004
Posts: 580
Likes: 0
From: Des Moines, Iowa
^ Yes you are.
Reply
Old Aug 15, 2007 | 10:23 PM
  #4  
Black1993rx7's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
 
Joined: May 2006
Posts: 136
Likes: 0
From: Indianapolis, IN
thank you guys.
Reply
Old Aug 16, 2007 | 06:25 PM
  #5  
bajaman's Avatar
Constant threat
Tenured Member 20 Years
 
Joined: Jul 2001
Posts: 4,968
Likes: 39
From: near Wichita, Kansas
Sometimes testing like this is a bit inconclusive as you are relying on a very inaccurate 'pressure comparitor', i.e. your mouth, to make the assumption if there is ANY bleed-off or not.
I suggest either hooking up a small pump and short length of hose that has a pressure gauge on it, and pump it up to 5 psi or so and then watch it for a minute or so.
If you DO decide to just blow thru it, hook up a short length of hose, blow thru the HOSE, not the valve as your lips make a better seal. And you could take a cigarette or something else that has a smoke trail and use it to see if the valve is leaking by directing the exit of the valve towards the smoke.
Reply
Old Aug 16, 2007 | 11:01 PM
  #6  
jmadams74's Avatar
Senior Member
Tenured Member 15 Years
 
Joined: Oct 2002
Posts: 526
Likes: 5
From: Atlanta
or. . .if you have them off already to check, you could just replace them with the really good (and inexpensive $15-$20) sets that Dale Clark sells and not worry again for a long, long time!
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
SakeBomb Garage
SakeBomb Garage
9
May 11, 2020 10:04 AM
Jeff20B
1st Generation Specific (1979-1985)
73
Sep 16, 2018 07:16 PM
Bauer778
3rd Generation Specific (1993-2002)
10
Nov 4, 2015 04:42 PM
alexdimen
3rd Generation Specific (1993-2002)
20
Oct 23, 2015 01:50 PM


Thread Tools
Search this Thread

All times are GMT -5. The time now is 06:55 AM.