3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

PLEASE HELP!...can only get 7 PSI with AVC-R

Thread Tools
 
Search this Thread
 
Old Nov 6, 2002 | 09:26 AM
  #1  
abmFD's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Sep 2002
Posts: 67
Likes: 0
From: VA
PLEASE HELP!...can only get 7 PSI with AVC-R

I recently had an Apex'i AVC-R installed in my 94 FD. In monitor mode with the settings off, I can only boost at 7 PSI (.53 kg/cm^2) even above 4500 rpm. I thought that I had a vaccum leak somewhere but last night I set the controller to boost at 9 PSI just to see if the controller was working properly but it stayed the same. Then I tried to lower the boost but my turbos still boosted at 7. So it seems like I can't control boost at all.

I did a search for AVCR and could not find anything that would remedy my problem. I have carefully read the information posted on the following web sites:

http://www.scuderiaciriani.com/rx7/AVC-R_install.html
http://www.rx7turboturbo.com/robrobi..._r_install.htm

Could someone please help me find a solution to this problem? The controller is wired properly to the ECU because it monitors all the parameters its suppossed to properly. I have disconnected the factory solenoids and have properly plugged them both.

THANKS IN ADVANCE!
Reply
Old Nov 6, 2002 | 09:28 AM
  #2  
GsrSol's Avatar
Z06 powered FD
Tenured Member 10 Years
 
Joined: Mar 2001
Posts: 1,883
Likes: 0
From: Dallas, Texas
You can't lower the boost past 7. Disconnect what solinoids?
Reply
Old Nov 6, 2002 | 09:37 AM
  #3  
abmFD's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Sep 2002
Posts: 67
Likes: 0
From: VA
I plugged both hoses that were connected to the wastegate and precontrol actuator ports. Sorry for the misleading sentence.
Reply
Old Nov 6, 2002 | 09:48 AM
  #4  
GsrSol's Avatar
Z06 powered FD
Tenured Member 10 Years
 
Joined: Mar 2001
Posts: 1,883
Likes: 0
From: Dallas, Texas
I think you're only suppose to plug one (wastegate) but you should still get more then 7psi on the second turbo.
Reply
Old Nov 6, 2002 | 01:31 PM
  #5  
rxrotary2_7's Avatar
Lives on the Forum
Tenured Member 20 Years
 
Joined: May 2001
Posts: 5,097
Likes: 1
From: southern NJ
do you hear your solinoid from the avc-r "clicking" when the boost comes on? if no...start your troubleshooting there. if your solinoid is not operating corectly, you will not see more than 7psi no matter the setting.
if i remember correctly with the stock twins you should be pluging both.
Reply
Old Nov 6, 2002 | 02:02 PM
  #6  
abmFD's Avatar
Thread Starter
Full Member
Tenured Member 20 Years
 
Joined: Sep 2002
Posts: 67
Likes: 0
From: VA
Yes, I do hear the solenoid clicking. I'll probably have to remove the solenoid and blow through it to see if there is air flow.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Turblown
Vendor Classifieds
12
Oct 17, 2020 03:25 PM
Logan Reinisch
General Rotary Tech Support
44
Sep 17, 2018 12:20 PM
LongDuck
1st Generation Specific (1979-1985)
12
Oct 7, 2015 08:12 PM




All times are GMT -5. The time now is 09:21 PM.