fans are running and not running

I´m new to FD3S but I´m learning, the club is a big big help. First of all I´ve used serch on the forum to help me understand the cooling problem in my rx7. from that I found out that the 4 blade fan was not running. So I check the wires and found that they were the problem. fixed that.....( thought I did )
Today I still have some problem, the thing is when my test drive was over the 4 blade fan was again not working and the 5 blade did not stop runnig. I waited for like 2 minutes and the took the battery off and put it back on to let it stop, I also (knock lightly) on the four relaysboxes for the fan and when I did the fan slowed down.
can I link the problem straight to bad relay?? can a bad relay make the other fan running and running and the other one not running? Or what is it?

thanks to you guys and the club
Reply
Old Jul 14, 2006 | 11:17 AM
  #2  
dgeesaman's Avatar
Moderator
Tenured Member: 20 Years
Liked
Loved
iTrader: (8)
 
Joined: May 2002
Posts: 12,313
Likes: 27
From: Hershey PA
Yep, that definitely sounds like bad relays. Also keep checking for open are shorted wiring.

Dave

Last edited by dgeesaman; Jul 14, 2006 at 11:20 AM.
Reply
Old Jul 14, 2006 | 01:09 PM
  #3  
rapidNO's Avatar
Thread Starter
Junior Member
Tenured Member 05 Years
 
Joined: Mar 2006
Posts: 29
Likes: 0
From: Reykjavik
yeah, thanks dgeesaman, guess I´m going into a good fridaynight in the garage. I´m gonna go ovr all relays and wires
Reply
Old Jul 15, 2006 | 02:41 PM
  #4  
rapidNO's Avatar
Thread Starter
Junior Member
Tenured Member 05 Years
 
Joined: Mar 2006
Posts: 29
Likes: 0
From: Reykjavik
found out that the fan motor is not working. so I´m ordering a new one. nothing wrong with relays or wires, I got power to the last plug to the fan, so it must be the motor.
Reply
Old Jul 15, 2006 | 02:46 PM
  #5  
7racer's Avatar
Eats, Sleeps, Dreams Rotary
Tenured Member 15 Years
 
Joined: Apr 2001
Posts: 3,736
Likes: 10
From: Dallas, Texas
Good trouble shooting! NIce job!
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
streetlegal?
New Member RX-7 Technical
13
Mar 17, 2022 02:46 PM
immanuel__7
2nd Generation Specific (1986-1992)
89
Sep 5, 2015 10:23 AM
CaptainKRM
2nd Generation Specific (1986-1992)
14
Aug 26, 2015 09:52 PM




All times are GMT -5. The time now is 10:21 AM.