Cooling system pressure test...coolant leaking from overflow tank

Thread Tools
 
Search this Thread
 
Old May 14, 2018 | 09:34 PM
  #1  
dasalnt's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
iTrader: (2)
 
Joined: Oct 2001
Posts: 79
Likes: 0
From: orange county, ca
Cooling system pressure test...coolant leaking from overflow tank

I rented a cooling system pressure tester from autozone and used it tonight. I noticed that after I get to 12lbs of pressure the coolant starts to leak from the coolant overflow tank. Its not from the top but somewhere else in the tank. After about 30 mins the pressure drops to around 10. Im assuming there might be a crack in the plastic tank but I'm not sure. The dipstick shows the tank is full though. I replaced the radiator cap and the aftermarket ast cap. Im thinking as I pressurize the system the coolant in the ast is being pushed into the overflow causing it to leak out. I originally tested it to check if I had a coolant leak becuse every couple days I get a low coolant light even though I didn't see any visible leaks. Any ideas what might be going on. Now im worried I have a blown seal. Thanks for any help.
Reply
Old May 14, 2018 | 09:45 PM
  #2  
dasalnt's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
iTrader: (2)
 
Joined: Oct 2001
Posts: 79
Likes: 0
From: orange county, ca
Heres a pic

Reply
Old May 14, 2018 | 10:58 PM
  #3  
jza80's Avatar
Rotary Enthusiast
Tenured Member: 10 Years
Liked
Loved
Community Favorite
iTrader: (32)
 
Joined: Nov 2011
Posts: 842
Likes: 115
From: South Orange County, CA
I’m guessing your AST pressure cap is venting off at about 10psi or less. Maybe try a new cap?
Reply
Old May 14, 2018 | 11:36 PM
  #4  
adam c's Avatar
Cheap Bastard
iTrader: (2)
 
Joined: Sep 2002
Posts: 8,368
Likes: 50
From: San Luis Obispo, Ca
How many miles on your engine? Is it an original engine or a rebuild?
Reply
Old May 15, 2018 | 10:24 AM
  #5  
mdp's Avatar
mdp
Always Bad Advice
Tenured Member: 20 Years
Liked
Loved
 
Joined: Nov 2005
Posts: 327
Likes: 87
From: San Diego
After the coolant recall your RX-7 should be equipped with a 0.9 bar (13psi) radiator cap on the AST. Given the vagaries of manufacturing tolerances and the inaccuracies of your Autozone Test gauge releasing pressure at a indicated 12 psi wouldn't be unusual. As for the disappearing coolant. What does the exhaust look and smell like? You can also take it to a shop to test and see if there is combustion byproducts in the coolant.

Last edited by mdp; May 15, 2018 at 10:45 AM. Reason: spelling
Reply
Old May 15, 2018 | 09:04 PM
  #6  
DaleClark's Avatar
RX-7 Bad Ass
Tenured Member: 20 Years
Liked
Loved
Community Favorite
iTrader: (56)
 
Joined: Jan 2002
Posts: 15,622
Likes: 2,725
From: Pensacola, FL
First, when you do the coolant pressure test it needs to be done on the AST not on the fill cap like in your picture. The radiator cap will have a spring rated for 12-14 PSI or so and when you pump up the system with that tester it pushes the bottom part of the cap up and forces coolant into the overflow.

It is possible the overflow tank is cracked or damaged. Make sure the tank isn't overfull, you want it about half way on the full/low mark. If it's all the way to the top that's no good.

If you're leaking coolant most times you can smell it or see steam or whatever from the leak.

Dale
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Va Rx-7
3rd Generation Specific (1993-2002)
20
May 15, 2009 06:26 PM
TRWeiss1
3rd Generation Specific (1993-2002)
16
Jun 3, 2007 12:15 PM
85 FB
1st Generation Specific (1979-1985)
6
Apr 12, 2006 03:45 PM
PureMdMa
3rd Generation Specific (1993-2002)
34
Aug 23, 2004 03:45 PM
LT1-7
General Rotary Tech Support
3
Aug 2, 2001 05:59 AM




All times are GMT -5. The time now is 07:18 PM.