3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

Coolant problem solved

Thread Tools
 
Search this Thread
 
Old Aug 5, 2003 | 12:50 AM
  #1  
Street King's Avatar
Thread Starter
*** Bless Texas!
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 775
Likes: 0
From: TX
Thumbs up Coolant problem solved

Well I couldn't find my old thread to add onto it so I started another one.

As you may know I had a problem of coolant being spit up out of the overflow resevior tank after I took the car for a drive and stopped it. I would have to add about a quart of coolant/water everytime I drove her. Well I KNEW it wasn't my seals going. It just couldn't be, I never had to add coolant ever to my car until this happened and what not.

Called Ray up at Malloy Mazda and put an order for every coolant hose I needed and a new coolant resevior tank along with new filler neck cap and a new thermostat. Called Jason up and ordered a aluminum AST(yes I know, a long time coming). Put the parts in over the weekend.

When I took my coolant overflow tank out it was filthy and there was a layer of sediment on the bottom of it, looked like dirt. Anyways after a good flush cause the rad only had about 2k miles on it I didn't want to change it out yet. Put everything back together. Burped it a few times. Drove it around and burped it a few more times over the course of a couple of days. It's all good now and holding coolant down. No spitting up what so ever.

I wanted to change the cooling system before I would except defeat of a blown coolant seal. I'am glad I did because I just put in a new clutch and alum flywheel and now that it's broken in I can enjoy it now.

Anyways to all the people that said I had a blown seal.... I suggest unless it's completly obvious that a seal is blown, change all your hoses and such and make sure it is NOT your coolant system before you drop the big bucks on a new motor. That's my story.
Reply
Old Sep 15, 2004 | 01:33 AM
  #2  
exitium's Avatar
EX efini driver
Tenured Member 05 Years
 
Joined: Jan 2004
Posts: 25
Likes: 0
From:
i'm having the same problem now, but how do the changes you made fix the problem?

it's something i'm considering looking into for sure, but i'm wondering:
how did new hoses and such help?

or was it the new AST?
Reply
Old Sep 15, 2004 | 01:53 AM
  #3  
InsaneGideon's Avatar
Still on 1st engine
Tenured Member 05 Years
 
Joined: Jun 2003
Posts: 1,176
Likes: 1
From: SoCal
If you have a search around, it's quite common for coolant system leaks (often non-o-ring-related) to allow air into the system when the car cools, yet not produce noticeable coolant leakage.

I learned this the hard way as I was leaving for SevenStock7. I stayed home testing things out, ended up replacing the filler-neck cap. I was hearing air in the heater core for a week before. I haven't heard it since replacing the cap Saturday. Oh well, I guess I got off lucky with a $10 fix.
Reply
Old Sep 15, 2004 | 03:50 AM
  #4  
BlueRex's Avatar
Rotary Freak
Tenured Member 05 Years
 
Joined: Sep 2004
Posts: 2,444
Likes: 0
From: Bay Area, CA
Originally Posted by Street King
When I took my coolant overflow tank out it was filthy and there was a layer of sediment on the bottom of it, looked like dirt.
I noticed this too when I examined my reservoir. This was reason enough to prompt a good flush of the system. I wonder how that stuff gets in there
Reply
Old Sep 15, 2004 | 04:49 AM
  #5  
RE Suzuki's Avatar
I speak Japanglish
Tenured Member 05 Years
 
Joined: Jul 2004
Posts: 1,214
Likes: 1
From: bayarea, ca
dirty coolent? maybe your o-ring is shot and theres oil leaking into the coolent system. I fixed by problem by gettin a new motor...^.^

Last edited by RE Suzuki; Sep 15, 2004 at 04:52 AM.
Reply
Old Sep 15, 2004 | 05:56 AM
  #6  
cruiser's Avatar
Rotary Freak
Tenured Member 05 Years
 
Joined: Dec 2002
Posts: 2,522
Likes: 0
From: Slovenia, Europe
I had same thing happening to me because once my contact on the coolant level sensor got bad I removed the filler neck cap and then coolant started coming out of overflow tank. Then I never really filled it up correctly until I found out that when filling in the coolant, I also need to open the AST cap and fill coolant (at filler neck) until it overflows at AST, then close AST and fill at filler neck up to top.

Never had a problem since
Reply
Old Sep 15, 2004 | 09:37 AM
  #7  
AznPhoenix's Avatar
Rotary Enthusiast
Tenured Member 05 Years
 
Joined: Aug 2003
Posts: 798
Likes: 1
From: Rpv, CA.
im having the same problem, but one piece of info id like to get an opinion on is that when i was getting my radiator flushed, thinking maybe a good flush is what my car needed, they would put coolant in the thermostat while the engine was running. It would not take it easily - it would repeatedly be pushed out by pressuarized air. The service guy even said that its unusual to have so uch pressure in the coolant system. I was also told it was my water seal in the engine, but could new hoses n such solve my problem which is basically js like urs? I also noticed sediment in my resivior tank and also hear boiling coolant rushing to resivior tank after i turn the engine off, or after a 5-10 mile drive even keeping the rpm below 5000. Let me know if your solution could work for me also. thnx
Reply
Old Sep 15, 2004 | 02:26 PM
  #8  
BlueRex's Avatar
Rotary Freak
Tenured Member 05 Years
 
Joined: Sep 2004
Posts: 2,444
Likes: 0
From: Bay Area, CA
Originally Posted by RE Suzuki
dirty coolent? maybe your o-ring is shot and theres oil leaking into the coolent system. I fixed by problem by gettin a new motor...^.^
Yea that's what I suspected. It's been a good 2 months since I did that flush and have since not had any problems so hopefully this leak is only in the beginning stage. Either way I'm ready to absorb the cost of a new motor if that's what it comes to
Reply
Old Sep 15, 2004 | 02:31 PM
  #9  
fd3s_rx7's Avatar
Rotary Freak
Tenured Member 20 Years
iTrader: (13)
 
Joined: Oct 2003
Posts: 2,022
Likes: 0
From: Sac., CA
that's good that you found the problem to it...
Reply
Old Sep 15, 2004 | 05:13 PM
  #10  
mecman's Avatar
Senior Member
Tenured Member: 20 Years
iTrader: (12)
 
Joined: Jun 2001
Posts: 676
Likes: 24
From: Chicago, IL, USA
I have the same problem. I notice the hose going to the top of my aluminum AST was cracked. I cut off the end and reclamped it. No problems for a month and then it started again. I think I just need to replace those smaller hoses going to and from the AST.
Reply
Old Sep 15, 2004 | 06:35 PM
  #11  
gambit023's Avatar
Full Member
Tenured Member 05 Years
 
Joined: Jan 2003
Posts: 160
Likes: 0
From: New York, NY
Streetking:

Please keep us posted on whether this fix is still working for you. I did the same thing you did and everything seemed to be working fine and all until the reservoir started filling up again…then the coolant spill syndrome started all over again.

Thanks dude.
Reply
Old Sep 20, 2004 | 01:34 PM
  #12  
jeremyb's Avatar
Hi....
Tenured Member 15 Years
 
Joined: Mar 2004
Posts: 845
Likes: 0
From: bay area
i had a similar problem with my system. I had all te symptoms. Crazy layer of sediment in my overflow resovior, start ups with extreme bogging, cooalnt being spit through the overflow tube followed by 5 minutes of air hissing and nurmerous times of filling the system back up with water/coolant. So I did the block-weld fix. And after a day of doing the procedure, and a night of letting the block weld sit, it worked. I had no bogging at start up anymore and no coolant/sir spitting after the engine goes off. Yet a week after this fix i was driving to take my gf out for lunch, and my engine temp goes crazy high.(keep in mind this is with the stock temp guage... and i still had no bogging at start up) So I decide to go home. So as I was getting onto the on-ramp for the freeway i heard a loud pop.....(yes my heart began to beat like a hamsters.) The pop was then followed by a small puff of smoke going out of the side of my hood. So I pull over and the first thing I see is a ripped belt. (uhm the one next to the air pump and whatver else its turning). And right next to that i see a blown upper radiator hose. It was just straight popped off its other half. i had collant all over the place from the direction the hose fired. Anyone got an ideas how this happened? What pressurized the system so much to to that?
Reply
Old Sep 20, 2004 | 08:50 PM
  #13  
wrankin's Avatar
Old Rotary Dog
Tenured Member 15 Years
 
Joined: Feb 2003
Posts: 1,461
Likes: 2
From: Durham, NC
Ummm, check your water pump perhaps?
Reply
Old Sep 20, 2004 | 09:02 PM
  #14  
busy13b's Avatar
Om Namah Shivaya
Tenured Member 20 Years
iTrader: (5)
 
Joined: Feb 2001
Posts: 519
Likes: 1
From: Portland, OR
Originally Posted by jeremyb
Anyone got an ideas how this happened? What pressurized the system so much to to that?
13 pounds of force per sqaure inch probably just had it's way with an old and extremely warn-out radiator hose!!!
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Jeff20B
1st Generation Specific (1979-1985)
73
Sep 16, 2018 07:16 PM
sinistersam
New Member RX-7 Technical
5
Sep 13, 2015 07:17 PM
ZaqAtaq
New Member RX-7 Technical
2
Sep 5, 2015 08:57 PM
vmerino
2nd Generation Specific (1986-1992)
0
Sep 5, 2015 11:26 AM