Unhappy A/C problem.

Ok well I just recharged my A/C with R-134a. Worked fine for a few days. Then I took out my air pump and now my a/c alternates on and off when I turn it on. Just cruising you can feel the power loss and gain when the a/c kicks on and off every 3 secs.

It still blows air at the same rate but the compressor is kicking on and off kinda fast, like I said every 3 secs. Turn off the A/C and the car runs and idles fine. I think it might be the compressor switch or do you think it's my whole compressor giving out(compressor clutch)?

I know these cars are notorious for things going wrong if you do anything to the car, like putting on a dp and then suddenly you get 2 psi and it's a different problem.

I'll connect my air pump back and let it idle and see if the compressor cuts on and off then later today.

Also a side not, I want to run a resistor for my air pump switch, what size do I need?

Jonas
Reply
Old Jun 18, 2003 | 07:11 PM
  #2  
Street King's Avatar
Thread Starter
*** Bless Texas!
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 775
Likes: 0
From: TX
C'mon guys I really need some advice on this one.
Reply
Old Jun 19, 2003 | 12:04 AM
  #3  
wonder1and's Avatar
I Sold My Car 2 the Devil
Tenured Member 20 Years
 
Joined: Oct 2001
Posts: 2,361
Likes: 0
From: Duncanville, Tx
you've go the wrong amount of freon in your system... it should be @ 85% of what is required for the R-12... Also check your viewer on your dryer... (little window) and look for the green gas. If you don't see any when the pump is on... the tubes are empty and youve got a leak.
Good luck,
Ryker
Reply
Old Jun 19, 2003 | 12:18 AM
  #4  
Street King's Avatar
Thread Starter
*** Bless Texas!
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 775
Likes: 0
From: TX
Originally posted by wonder1and
you've go the wrong amount of freon in your system... it should be @ 85% of what is required for the R-12... Also check your viewer on your dryer... (little window) and look for the green gas. If you don't see any when the pump is on... the tubes are empty and youve got a leak.
Good luck,
Ryker
K thanks. Do you know the amount of lbs required for R-12? You might be right on adding to much, I know it's just as bad as if not adding enough. Ihope I didn't **** up anything on my a/c. I filled it up till the bubbles went away in the glass eye.When the a/c was working, it never looked green to me, but I know it's supposed to be. I'll take some out.

I apreciate your help.
Reply
Old Jun 19, 2003 | 07:22 AM
  #5  
Full Member
Tenured Member 10 Years
 
Joined: Mar 2001
Posts: 92
Likes: 0
From: Sunrise, FL
Do you have gauges? One thing that is a fact of R134A is it has a higher condensing pressure. If the high side gets to around 375 PSI approx, the compressor high side switch will disengage the compressor. And the highside pressure is directly related to outside temp and airflow through the condensor. If it was working fine and it was just a little cooler outside, that could be it. Is your condensor/Radaitor in stock location? You need tons of AIRFLOW through the condensor for it to work well.
Reply
Old Jun 19, 2003 | 10:21 AM
  #6  
Street King's Avatar
Thread Starter
*** Bless Texas!
Tenured Member 05 Years
 
Joined: Jan 2002
Posts: 775
Likes: 0
From: TX
Originally posted by yellowbird
Do you have gauges? One thing that is a fact of R134A is it has a higher condensing pressure. If the high side gets to around 375 PSI approx, the compressor high side switch will disengage the compressor. And the highside pressure is directly related to outside temp and airflow through the condensor. If it was working fine and it was just a little cooler outside, that could be it. Is your condensor/Radaitor in stock location? You need tons of AIRFLOW through the condensor for it to work well.
Yes I have gauges, well my father does cause thats part of his job. We couldn't find the amount needed to add to an R-134a system. We pulled the old freon, vaccumed it for a good 30 mins and refilled it with oil/freon R-134a. I will take some out and see what happens. rad./condensor is in it's stock location.
Reply
Old Jun 19, 2003 | 10:34 AM
  #7  
r0gu3's Avatar
Boostless FD
Tenured Member 20 Years
 
Joined: Mar 2001
Posts: 1,693
Likes: 0