2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.

starter problems

Thread Tools
 
Search this Thread
 
Old Apr 25, 2005 | 06:09 PM
  #1  
vicious525E's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
 
Joined: Oct 2002
Posts: 142
Likes: 0
From: spring hill, tennessee
starter problems

ok, this has sort of got me a little confused. the starter signal cable is reading 14V when the car is in the run position, which is weird for one, but it is also reading 14V in the start postion which is normal i would think, but ether way the starter motor isnt cranking at all. so i was thinking it could be the solonoid but that still doesnt explain why that wires reading 14v in the run position....i need to sleep
Reply
Old Apr 25, 2005 | 06:23 PM
  #2  
ilike2eatricers's Avatar
I R SAD PANDA W/O BAW
 
Joined: Nov 2002
Posts: 6,061
Likes: 1
From: bay area
Clutch bypass switch? Does it make a click sound when you try to crank?
Reply
Old Apr 25, 2005 | 06:29 PM
  #3  
vicious525E's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
 
Joined: Oct 2002
Posts: 142
Likes: 0
From: spring hill, tennessee
yep, sounds like its comming from the right side near the fire wall, could the neutral safty switch be the problem?

Last edited by vicious525E; Apr 25, 2005 at 06:50 PM.
Reply
Old Apr 25, 2005 | 06:51 PM
  #4  
WAYNE88N/A's Avatar
Lives on the Forum
Tenured Member 05 Years
 
Joined: Feb 2004
Posts: 5,721
Likes: 3
From: Coldspring TX
What are you calling the "signal" wire? The run from the ignition switch? If so, when the key is turned and the solenoid energizes, the voltage should fall to 0 (because the circuit is grounded now). If the voltage stays the same (as long as you're reading it before the solenoid) as the key is turned, then the component (in this case the solenoid) isn't energizing...

Make any sense???
Reply
Old Apr 25, 2005 | 06:59 PM
  #5  
vicious525E's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
 
Joined: Oct 2002
Posts: 142
Likes: 0
From: spring hill, tennessee
ya, the wire running from the ignition into the starter solenoid, and i didnt get to test it pluged in, but what im wondering is why its showing anything above 0 volts with it in the "run" position, which would be the position before the start position, or all the way over. i would think that i would only see voltage when the key would be in the start position.

Last edited by vicious525E; Apr 25, 2005 at 07:01 PM.
Reply
Old Apr 25, 2005 | 07:18 PM
  #6  
HAILERS's Avatar
HAILERS
Tenured Member 10 Years
 
Joined: May 2001
Posts: 20,563
Likes: 27
From: FORT WORTH, TEXAS,USA
Probably backfeeding thru a blower moter relay. Insignificant.
Reply
Old Apr 25, 2005 | 07:44 PM
  #7  
vicious525E's Avatar
Thread Starter
Full Member
Tenured Member 15 Years
 
Joined: Oct 2002
Posts: 142
Likes: 0
From: spring hill, tennessee
cool, that was more so the answer i was looking for, im sure the solenoid is ether bad or just stuck, it has been a few years since it has been engaged. i'll take it to advanced tomarrow and have it tested and replace if needed.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
gxl90rx7
Haltech Forum
6
Jun 30, 2017 11:30 PM
Enzo1944
New Member RX-7 Technical
2
Sep 6, 2015 08:57 AM




All times are GMT -5. The time now is 12:00 PM.