2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.

Power Window Relay Mod Issue

Thread Tools
 
Search this Thread
 
Old Mar 13, 2017 | 09:45 AM
  #1  
Gabriel82's Avatar
Thread Starter
xXxFC3SxXx
Tenured Member 15 Years
iTrader: (8)
 
Joined: Apr 2007
Posts: 707
Likes: 25
From: Pomona CA
Power Window Relay Mod Issue

Hi guys,

I was following the diagram for the power window relay modification. I placed to relays on each door. The issue I am coming across is that my master switch can only make the passenger window go up but it won't go down. Has anyone come across this issue? Does something need to be grounded or split?
Reply
Old Mar 13, 2017 | 10:47 AM
  #2  
RotaryEvolution's Avatar
Sharp Claws
Tenured Member 15 Years
iTrader: (30)
 
Joined: Oct 2003
Posts: 5,107
Likes: 50
From: Central Florida
was it working before you did the modification? if it goes down it should be able to go up, sounds like you either have the wiring wrong or your switch is kaput.


i sell premade kits for it if you continue having problems, but your wiring is probably hacked to bits now so that won't be of any help anymore.
Reply
Old Mar 14, 2017 | 11:25 AM
  #3  
Gabriel82's Avatar
Thread Starter
xXxFC3SxXx
Tenured Member 15 Years
iTrader: (8)
 
Joined: Apr 2007
Posts: 707
Likes: 25
From: Pomona CA
The switch was working prior starting the relay mod.
Reply
Old Mar 14, 2017 | 11:41 AM
  #4  
RotaryEvolution's Avatar
Sharp Claws
Tenured Member 15 Years
iTrader: (30)
 
Joined: Oct 2003
Posts: 5,107
Likes: 50
From: Central Florida
then you botched your wiring job, double check it all.
Reply
Old Mar 17, 2017 | 09:48 AM
  #5  
jjwalker's Avatar
MECP Certified Installer
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 3,176
Likes: 3
From: Mesquite, TX-DFW
You are missing either ground or 12v on your DOWN relay. 87a of each relay should always be ground. Most likely you don't have 12v at terminal 87 on your down relay. The only other thing would be a bad connection between the switch at terminal 86 of the down relay.

If the relay clicks when you press down on the switch but nothing happens, check voltage at pin 87. If the relay clicks, that rules out a lot of things.