heater motor changed

ok im assuming i replaced the right part so....
ok my heater wont blow out air no cold nor warm. when i adjust the speed i can hare it click by the switches. also all of the vents move when adjusting the feet face windshield etc. but i cant adjust the air coming out. just happened with the car sitting for a while. turned the car on and nothing coming out. so i posted on here and they said replace the motor. so i went and bought one it was like 50 bucks new. the only place i could see a motor like it was under the glove compartment under the passenger side. i hope that was the right thing cause it looked like it. after doing so still no heat. i assumed the black wire went with the black and the blue white one went with hte black yellow/orange one when hooking itup. either way no air coming out still. when i had the car on i switched the speed from on to off and put my hand down by the blower and you could feel the power it was getting kind of click im sure you know what i mean in the cables. i pulled the adjuster unit out and from what i could see and touched all those wires where fine. i saw no wires disconnected.
the fuse in the fuese box, the one of the two big ones had nothing poping out so i assued it was fine sence the red part has to be popping out right if something was wrong to reset it.

so can anyone point me in the right direction to fix this dam problem?
thanks for any help.
andy
Reply
Old Feb 29, 2004 | 07:31 PM
  #2  
midnightride42's Avatar
Thread Starter
Senior Member
Tenured Member 05 Years
 
Joined: Apr 2003
Posts: 396
Likes: 0
From: columbus ohio
anyone?
Reply
Old Feb 29, 2004 | 07:50 PM
  #3  
Icemark's Avatar
Former Moderator. RIP Icemark.
 
Joined: Apr 2001
Posts: 25,896
Likes: 24
From: Rohnert Park CA
Please search, this has been covered many times before. The search function is found in the upper right hand corner of the page.

You would have found (if you had searched) that it is probably either a bad blower resistor, a bad logicon, or bad logicon amp if the fuses and circuit breaker are all good.
Reply
Old Mar 1, 2004 | 06:13 AM
  #4  
midnightride42's Avatar
Thread Starter
Senior Member
Tenured Member 05 Years
 
Joined: Apr 2003
Posts: 396
Likes: 0
From: columbus ohio
(bad blower resistor, a bad logicon, or bad logicon amp)
yes i did the search but seeing those items dont ring a bell in mind. so was hoping someone on here would catch that i dont anything about our cars. i needed as much help as i could get. so if someone could tell me where those are located and where i can get these items that would be great. i am assuming by the last post that i installed the blower in the correct place.
thanks again and i hope to have someone give me anser to the problem.
andy
Reply
Old Mar 1, 2004 | 09:59 AM
  #5  
Zach McAfee's Avatar
FTD Wanna Be
Tenured Member 10 Years
 
Joined: Jun 2002
Posts: 1,252
Likes: 0
From: Virginia
It's might be the logicon, which is a bear to change.
Reply
Old Mar 1, 2004 | 12:38 PM
  #6  
midnightride42's Avatar
Thread Starter
Senior Member
Tenured Member 05 Years
 
Joined: Apr 2003
Posts: 396
Likes: 0
From: columbus ohio
still waiting for one of these master minds to read this and anser all of my questions.
thanks again
andy
Reply
Old Mar 1, 2004 | 12:41 PM
  #7  
Icemark's Avatar
Former Moderator. RIP Icemark.
 
Joined: Apr 2001
Posts: 25,896
Likes: 24
From: Rohnert Park CA
I don't want to buy a shop manual for my car, is there a place where I can still find out the information from one
Shop manuals for both series can be found on-line at:
http://www.iluvmyrx7.com/2nd_gen_manuals.htm
and
http://www.fc3s.org/how_tos/manuals/88_fsm.html
http://www.fc3s.org/how_tos/manuals/89_fsm.html
http://208.62.166.66/guest/shop_manuals/
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Skeese
Adaptronic Engine Mgmt - AUS
65
Mar 28, 2017 03:30 PM
turbo-minivan
General Rotary Tech Support
69
Feb 4, 2016 12:29 AM
incubuseva
2nd Generation Specific (1986-1992)
14
Sep 3, 2015 12:37 PM
rexhvn
3rd Generation Specific (1993-2002)
0
Aug 19, 2015 02:59 AM
KAL797
Test Area 51
0
Aug 11, 2015 03:47 PM




All times are GMT -5. The time now is 06:38 PM.