fuel pump rewire question

I am gathering supplies to rewire my fuel pump and I just wanted to ask if there was any reason not to tie into the EGI fuse rather then doing a inline fuse from the battery?
Old 10-09-12, 12:16 PM
  #2  
FC guy

iTrader: (8)
 
Rob XX 7's Avatar
 
Join Date: Oct 2002
Location: Long Island, New York
Posts: 8,714
Received 16 Likes on 16 Posts
How would you tie into the EGI fuse?

usually people do it to run heavier power wire to the pump, and use a relay to switch it
Old 10-09-12, 12:25 PM
  #3  
Driving RX7's since 1979

iTrader: (43)
 
HOZZMANRX7's Avatar
 
Join Date: Aug 2001
Location: So Cal where the OC/LA/SB counties meet
Posts: 6,096
Likes: 0
Received 8 Likes on 8 Posts
^I get where the OP is coming from. He is leveraging into the EGI fuse in the main fuse box to also serve as the fuse for this alternate circuit for the fuel pump. Actually makes sense as you don't want the engine running if the pump isn't as there could be a fuel starvation (read leaning out) moment. The kind of thing that makes Turbo engines go POP!!

So long as you make a very secure connection at the main fuse box, I don't see a problem. I will say that many folks including myself simply leveraged into what is otherwise an empty slot in that same main fuse box to that same end.
Old 10-09-12, 12:45 PM
  #4  
Full Member
Thread Starter
iTrader: (11)
 
Dunnhopen's Avatar
 
Join Date: Dec 2009
Location: Saint Louis, MO
Posts: 71
Likes: 0
Received 0 Likes on 0 Posts
would I still need the relay since none of it is power unless the car is powered on anyway?
Old 10-09-12, 01:35 PM
  #5  
Moderator

iTrader: (1)
 
satch's Avatar
 
Join Date: Jun 2005
Location: tulsa,ok.
Posts: 11,738
Received 12 Likes on 11 Posts
All the fuses in the engine fuse box are constant power if that's what you're asking.
Old 10-09-12, 01:43 PM
  #6  
Full Member
Thread Starter
iTrader: (11)
 
Dunnhopen's Avatar
 
Join Date: Dec 2009
Location: Saint Louis, MO
Posts: 71
Likes: 0
Received 0 Likes on 0 Posts
Thought so, so yes relay and yes tie in to EGI fuse
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
trickster
2nd Generation Specific (1986-1992)
25
07-01-23 04:40 PM
Rotospectre
New Member RX-7 Technical
3
03-28-18 03:33 PM
alphawolff
1st Generation Specific (1979-1985)
17
11-17-15 05:57 PM



Quick Reply: fuel pump rewire question



All times are GMT -5. The time now is 11:53 AM.