Airconditioner problem

My series 4 turbo 2 now that it has an aftermarket ecu wired in, when the interior fan is turned off, the compressor runs whether the aircon switch is on or off. If the fan is on, I can turn the compressor on or off with the air con switch. Hence I need to start the car with the fan on and it is not helping my battery. The workshop who did this has not had this problem before.
My question is, does is anyone know if I can run a relay in the compressor wire somehow to solve this?
Old 04-20-03, 09:26 PM
  #2  
Engine, Not Motor

iTrader: (1)
 
Aaron Cake's Avatar
 
Join Date: Feb 2001
Location: London, Ontario, Canada
Posts: 29,789
Likes: 0
Received 108 Likes on 91 Posts
You can simply connect a normally open relay to the compressor clutch wire, and activate it via the 12V from the blower motor.

Or, a slightly better solution. If your aftermarket ECU has extra outputs, use one of them. That way, you can bypass the compressor during accelleration.
Old 04-20-03, 10:10 PM
  #3  
Full Member

Thread Starter
 
XTC7 turbo's Avatar
 
Join Date: Jan 2002
Location: Australia
Posts: 67
Likes: 0
Received 0 Likes on 0 Posts
would you take the wire from the 12v input into the blower motor or elsewhere?
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
WyomingTII
2nd Generation Specific (1986-1992)
12
09-28-15 10:32 AM
lnlreaper
2nd Generation Specific (1986-1992)
2
09-27-15 09:59 AM
The1Sun
1st Generation Specific (1979-1985)
7
09-18-15 07:13 PM
The1Sun
New Member RX-7 Technical
5
09-15-15 04:45 PM



Quick Reply: Airconditioner problem



All times are GMT -5. The time now is 12:22 PM.