2nd Generation Non-Technical and pictures Show off your car & view 2nd gen RX-7 pictures here.

When you got too much time on your hands, my 86-88 FC code reader!

Thread Tools
 
Search this Thread
 
Old Mar 1, 2016 | 08:46 PM
  #1  
Str3atWarrior's Avatar
Thread Starter
Full Member
Tenured Member 05 Years
iTrader: (1)
 
Joined: Jun 2014
Posts: 223
Likes: 26
From: Montreal, Canada
QC When you got too much time on your hands, my 86-88 FC code reader!

I used the plans that i found on FC3S Pro v2.0:&nbsp How-To - Zenki FC3S Error Codes







Cleaner than just wires and leds soldered together!

Total time, about 2 hours! Tested and working great! Total cost less than 5$!
Reply
Old Mar 5, 2016 | 10:33 AM
  #2  
R.O.D's Avatar
Forward, Always
Veteran: Army
Tenured Member: 20 Years
iTrader: (3)
 
Joined: Sep 2004
Posts: 1,033
Likes: 4
From: [REDACTED]
You could add two more to the front for 2nd injectors. Had that on my 1st FC. Came on when the 2nds were activated. Just to take up some more room in the face of the box.
Reply
Old Mar 5, 2016 | 12:09 PM
  #3  
Str3atWarrior's Avatar
Thread Starter
Full Member
Tenured Member 05 Years
iTrader: (1)
 
Joined: Jun 2014
Posts: 223
Likes: 26
From: Montreal, Canada
Originally Posted by R.O.D
You could add two more to the front for 2nd injectors. Had that on my 1st FC. Came on when the 2nds were activated. Just to take up some more room in the face of the box.
That's a good idea, i'll probably add that too!

I made that box in school because i wanted something cleaner than just leds and wires taped together. Was super useful to diagnose my TPS problem!
Reply
Old Mar 10, 2016 | 03:29 PM
  #4  
R.O.D's Avatar
Forward, Always
Veteran: Army
Tenured Member: 20 Years
iTrader: (3)
 
Joined: Sep 2004
Posts: 1,033
Likes: 4
From: [REDACTED]
Wasn't meaning to sound like I was cutting it down. Things badass. Good work!
Reply
Old Mar 17, 2016 | 07:08 PM
  #5  
unek87's Avatar
NA-BOOSTIN
Tenured Member 10 Years
 
Joined: Oct 2004
Posts: 1,200
Likes: 2
From: austin,tx
So just a question really I've always wanted to ask over the years but never did . Can you is just s normal light bulb or does it have to be led . May seem Dumb I know lol
Reply
Old Mar 17, 2016 | 08:20 PM
  #6  
jjwalker's Avatar
MECP Certified Installer
Tenured Member 05 Years
 
Joined: Feb 2009
Posts: 3,176
Likes: 3
From: Mesquite, TX-DFW
Originally Posted by unek87
So just a question really I've always wanted to ask over the years but never did . Can you is just s normal light bulb or does it have to be led . May seem Dumb I know lol
Has to be LED, the transistors that switch it on and off can't support more than 150mA. A light bulb would exceed that by an exceptional factor.
Reply
Old Mar 18, 2016 | 05:47 PM
  #7  
unek87's Avatar
NA-BOOSTIN
Tenured Member 10 Years
 
Joined: Oct 2004
Posts: 1,200
Likes: 2
From: austin,tx
Thank you sir
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
jakewah
New Member RX-7 Technical
16
Mar 15, 2016 11:56 PM
OleKnees
New Member RX-7 Technical
15
Mar 12, 2016 10:12 PM
Leeroy_25
3rd Generation Specific (1993-2002)
6
Feb 28, 2016 05:15 PM




All times are GMT -5. The time now is 02:48 PM.