1st Generation Specific (1979-1985) 1979-1985 Discussion including performance modifications and technical support sections

Mallory 4110 pump 4309 reg GSL-SE Tank pick up needed?

Thread Tools
 
Search this Thread
 
Old 08-01-10, 06:36 AM
  #1  
Senior Member

Thread Starter
 
mpk490p's Avatar
 
Join Date: Sep 2007
Location: UK
Posts: 419
Received 3 Likes on 3 Posts
Mallory 4110 pump 4309 reg GSL-SE Tank pick up needed?

Hi all i'm runing a 51IDA on a 13b 4port (Street ported motor) i have a new 4110 mallory pump and 4309 reg to install but need to match my return line to my feed to get it to run at the right pressure. i've heard the GSL-SE tanks have a larger (10mm/3/8") feed? and return?
A) can someone confirm
B) does anyone have a inlet for sale (Have a GSL-SE tank already)

thanks
Old 08-01-10, 11:59 AM
  #2  
Old Fart Young at Heart

iTrader: (6)
 
trochoid's Avatar
 
Join Date: Apr 2004
Location: St Joe MO
Posts: 15,145
Likes: 0
Received 7 Likes on 7 Posts
A) Half true, return line is slightly smaller than supply line, approximately 5/16".

Not sure what you mean by inlet, describe it.
Old 08-01-10, 02:31 PM
  #3  
I need a new user title

 
PercentSevenC's Avatar
 
Join Date: Oct 2005
Location: Yaizu, Japan
Posts: 2,646
Likes: 0
Received 0 Likes on 0 Posts
I'm running an MSD EFI pump with a 4309 reg set at 4.25 PSI base pressure, stock 5/16" send line, and a 5/16" return line that reduces to 1/4" to go into the stock return line on the 12A tank. Fuel pressure is stable.
Old 08-02-10, 01:33 PM
  #4  
Senior Member

Thread Starter
 
mpk490p's Avatar
 
Join Date: Sep 2007
Location: UK
Posts: 419
Received 3 Likes on 3 Posts
Originally Posted by trochoid
A) Half true, return line is slightly smaller than supply line, approximately 5/16".

Not sure what you mean by inlet, describe it.


sorry ment pick up
Old 08-02-10, 01:35 PM
  #5  
Senior Member

Thread Starter
 
mpk490p's Avatar
 
Join Date: Sep 2007
Location: UK
Posts: 419
Received 3 Likes on 3 Posts
Originally Posted by PercentSevenC
I'm running an MSD EFI pump with a 4309 reg set at 4.25 PSI base pressure, stock 5/16" send line, and a 5/16" return line that reduces to 1/4" to go into the stock return line on the 12A tank. Fuel pressure is stable.
thanks i was going to fit the larger lines to the tank and see how it went i do have a spare tank inlet so i may just get some 10mm lines put into that if needed
Old 08-13-11, 03:55 AM
  #6  
Senior Member

Thread Starter
 
mpk490p's Avatar
 
Join Date: Sep 2007
Location: UK
Posts: 419
Received 3 Likes on 3 Posts
just got some 3/8 pipe, will replace the feed and return unto the standard tank pick up (GSL) and see how it goes
Old 03-20-12, 11:04 AM
  #7  
Senior Member

Thread Starter
 
mpk490p's Avatar
 
Join Date: Sep 2007
Location: UK
Posts: 419
Received 3 Likes on 3 Posts
ok so i have made a new pick up and fitted new lines for the spec on the 4110 10mm / 3/8" I'm still seeing some issues with variable pressure, I'm measuring pressure at the regulator now the lines do go larger after the regulator to the carb -8 1/2" would i need to increase the pressure to compensate this or would it be easier to go -6 to match?
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
alphawolff
1st Generation Specific (1979-1985)
17
11-17-15 05:57 PM
Alan777
3rd Generation Specific (1993-2002)
1
08-13-15 02:47 AM
baconflavored
SE RX-7 Forum
0
08-12-15 12:07 AM



Quick Reply: Mallory 4110 pump 4309 reg GSL-SE Tank pick up needed?



All times are GMT -5. The time now is 05:32 AM.