2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

Power Window Relay Mod Issue

Thread Tools
 
Search this Thread
 
Old 03-13-17, 09:45 AM
  #1  
xXxFC3SxXx

Thread Starter
iTrader: (8)
 
Gabriel82's Avatar
 
Join Date: Apr 2007
Location: Pomona CA
Posts: 706
Received 24 Likes on 20 Posts
Power Window Relay Mod Issue

Hi guys,

I was following the diagram for the power window relay modification. I placed to relays on each door. The issue I am coming across is that my master switch can only make the passenger window go up but it won't go down. Has anyone come across this issue? Does something need to be grounded or split?
Old 03-13-17, 10:47 AM
  #2  
Sharp Claws

iTrader: (30)
 
RotaryEvolution's Avatar
 
Join Date: Oct 2003
Location: Central Florida
Posts: 5,107
Likes: 0
Received 41 Likes on 40 Posts
was it working before you did the modification? if it goes down it should be able to go up, sounds like you either have the wiring wrong or your switch is kaput.


i sell premade kits for it if you continue having problems, but your wiring is probably hacked to bits now so that won't be of any help anymore.
Old 03-14-17, 11:25 AM
  #3  
xXxFC3SxXx

Thread Starter
iTrader: (8)
 
Gabriel82's Avatar
 
Join Date: Apr 2007
Location: Pomona CA
Posts: 706
Received 24 Likes on 20 Posts
The switch was working prior starting the relay mod.
Old 03-14-17, 11:41 AM
  #4  
Sharp Claws

iTrader: (30)
 
RotaryEvolution's Avatar
 
Join Date: Oct 2003
Location: Central Florida
Posts: 5,107
Likes: 0
Received 41 Likes on 40 Posts
then you botched your wiring job, double check it all.
Old 03-17-17, 09:48 AM
  #5  
MECP Certified Installer

 
jjwalker's Avatar
 
Join Date: Feb 2009
Location: Mesquite, TX-DFW
Posts: 3,176
Likes: 0
Received 2 Likes on 2 Posts
You are missing either ground or 12v on your DOWN relay. 87a of each relay should always be ground. Most likely you don't have 12v at terminal 87 on your down relay. The only other thing would be a bad connection between the switch at terminal 86 of the down relay.

If the relay clicks when you press down on the switch but nothing happens, check voltage at pin 87. If the relay clicks, that rules out a lot of things.