Fuel setup: guidance needed
1 Attachment(s)
I'm trying to plan out my fuel setup and could use some guidance. I have knight sport hybrid turbo, ID725/2000, and powerFC for my S4 T2. I've purchased the risingRPM fuel rail kit.
I've searched, but can't seem to get actual facts on parallel vs series fuel setup.? What do you guys think about my mockup running them in parallel with the fpr mounted on the oil block? Comments, concerns and advice greatly appreciated. http://i879.photobucket.com/albums/a...FCFuelFlow.jpg Also, I was recommended by my builder to get "the aeromotive" fuel pressure regulator. It seems to also be a regular choice by most on here. There is the A1000-6 and the A1000. The difference between the two seems to be the inlet ports. Which inlet port would be better for my application? A1000-6
A1000
RisingRPM fuel rails and oil block
Thank you for your advice! |
This won't really answer your question but I run 2 walbros with one going to the stock fuel line to the secondary rail only, and the other running through the egr hard line to the primary only going out to a Mallory fpr.
Clean,simple and cost effective. |
Run Parallel. easy and less pressure drops
|
your out of control.
|
now to answer your question 1 setup runs 1 line to the primary that connects to the secondary. which would be series. so you can run the stock lines no problems. in parallel you run 2 pumps using 2 feed lines and 1 more for return. you dont need to go parallel. again your out of control lol.
|
parallel has NOTHING to do with the number of fuel pumps and EVERYTHING to do with making the fuel rail system a RING MAIN
if you are unaware of these concepts , dont comment my experience with these setups on the car is over more than a decade, ( closer to 15 years ) and my background is refinery reticulation and process control , both of which qualify me to comment the OP's picture is all serial flow , counter current a parallel setup will equalise pressure and individual flows ( if at same pulse-widths ) across all the injectors regardless of the flow rate ie the factory serial path may amount to significant flow differential across the 4 injectors , especially if using high pulse-width with large injectors and only the s4 fuel rails ( s5 fuel rails have a larger volume which helps with instant surges in the pressure ) consider the factory serial path as an open hose,, pinched slightly at the end,, with 4 big sprinklers along its length -try it- ,, flow is NOT equal across these "injectors" the parallel set up is akin to the fire main/ ring main used in the local store no matter where you stand,, all sprinklers spray equally and if the supply from one direction is insufficient,, it is made up by flow coming from the other direction IE the pipe can rupture totally and the sprinklers either side of the rupture will still be at full flow EG ,, if your primarys are in hold mode at a large pulse-width ,, the secondarys will not suffer in flow or rail pressure and in fact be supplied backwards from the reg rather than past the two open injectors a parallel system is basically splitting your supply pipe to 2 with a tee and feeding EACH rail individually,, with EACH exit from that rail teeing together at the regulator ( either with tee,, or across both IN ports on the reg ) and this system is highly recommended if you run large injectors, ESPECIALLY with only the small diameter s4 fuel rails |
i didnt know there had to be a qualification to comment on fuel. i must have missed that. regardless it is not needed for the power level he is at. if he wants to run them like that it is fine. in my eyes it just complicates things. you only really notice these issues of all the injectors not spraying fully is in a returnless system. if you are sucking the rail dry on a injector pulse you need a stronger fuel pump.
|
When possible I would always run all rails parallel.
|
|
If you're set on using that oil filter adapter, I would run the lines in parallel like this:
http://i434.photobucket.com/albums/q...it_mounted.jpg |
Preheating the fuel by using that oil filter thing, looks like another possible spot for a leak too..
|
Elliot,
Preheating, maybe, but since the lines only pass through that adapter instead of connect to it with fittings, I don't think it's an additional leak point. |
Originally Posted by Turblown
(Post 10950476)
Preheating the fuel by using that oil filter thing, looks like another possible spot for a leak too..
|
Originally Posted by tuscanidream
(Post 10949283)
I'm trying to plan out my fuel setup and could use some guidance. I have knight sport hybrid turbo, ID725/2000, and powerFC for my S4 T2.
Are you planning to go bigger? You blew a lot of money already... isn't there something else on the car you could fix with all that cash? |
Would rather over kill the fuel system then kill over the engine!!
|
There's overkill and then there's ridiculous.
All the fuel in the world still comes secondary to a tune. What a shame it would be to waste money on an overkill fuel system and not be able to afford a decent tune, which ultimately leads to a blown motor... |
I hate to see anyone use any parts that have NPT fittings on them..
|
Originally Posted by FullFunctionEng
(Post 10953761)
I hate to see anyone use any parts that have NPT fittings on them..
|
run parallel
|
Originally Posted by RexRyder
(Post 10955052)
I use npt fittings on my wastegate lines and oil cooler, seems to be working good!
|
All times are GMT -5. The time now is 03:23 PM. |
© 2024 MH Sub I, LLC dba Internet Brands