Wanna use your full-range TPS?
Keeping in mind that the full-range TPS isn't used for accelerator pump duties unless you're running in TPS load mode in vacuum, some people (myself included) wish to use the stock full-range TPS for datalogging and the like.
The Microtech diagram for the 13BT instructs you to use the narrow-range sensor in both S4 and S5 applications. In order to use the full-range, use the following colors: stock sensor - use - MT harness Blue - ground - Brown Pink - +5 VDC (Vref) - Blue Yellow - signal - Grey Buena suerte! Brandon BR7 Racing |