AEM 315 Nozzel Flow Test
The AEM adjustents screws are small and are not very accurate. I used an accurate gauge to adjust the low pressure turn on points and the 16psi target boost value. The max value was by the values on the controller. Test1: Low Setting = 5psi, High Setting = 38psi, Boost = 16psi, Flow = 360 ccm/m Test2:----------------10----------------------21---------------16-------------390 Test3:----------------10----------------------27---------------16-------------375 Test4:----------------10----------------------33---------------16-------------300 Test5:----------------10----------------------38---------------16-------------290 Deductions from tests: (1) As you set "turn on boost" lower, the target boost WI rate increases. Or set it higher and target boost WI rate decreases. (2) As you set "max boost" lower/closer to target boost, WI rate increases. Or set it higher and WI decreases. |