3rd Generation Specific (1993-2002) 1993-2002 Discussion including performance modifications and Technical Support Sections.
Sponsored by:

why everyone should rewire their fuel pump

Thread Tools
 
Search this Thread
 
Old 06-19-09, 08:45 PM
  #1  
Sponsor
Thread Starter
iTrader: (41)
 
IRPerformance's Avatar
 
Join Date: Apr 2003
Location: NJ
Posts: 11,347
Received 317 Likes on 190 Posts
why everyone should rewire their fuel pump

How many of you have put a volt meter on the fuel pump on a dyno? I saw something scary this past week. Car I was having tuned had 550s/1680s, aeromotive fpr, supra tt pump, new oem fuel filter. Should have been enough fuel for close to 500 rwhp.around 16 psi boost we hit 100% injector duty cycle. Base fuel pressure was 40 psi.Car should have had injector to spare. I watched the fuel pressure gauge and under boost it shot to 60 psi and by 5000 rpm started falling. Fuel pressure fell as low as 40 psi.This explained why we had to add so much fuel at the top of the map. Next I put a volt meter on the fuel pump and was shocked to see just over 11v! Made no differnce if it was at idle ore wot. Car has a new alternator and odyssey 925 battery. Voltage on datalogit was over 12v at all times. This shows how much voltage drop there is in the junk factory wiring, As these cars age and are tampered with it gets worse.The fuel pump should have over 13v. This is another reason motors blow.
The following 2 users liked this post by IRPerformance:
ColdFeet (05-16-22), palthyboy (06-21-21)
Old 06-19-09, 09:12 PM
  #2  
Talk to me....

iTrader: (2)
 
Uncle Hungry's Avatar
 
Join Date: Sep 2007
Location: 600' up
Posts: 1,057
Received 51 Likes on 35 Posts
I agree, I removed mine from the ign harness first thing.
Old 06-20-09, 12:43 AM
  #3  
The shy megalomaniac

iTrader: (2)
 
NeoTuri's Avatar
 
Join Date: May 2003
Location: Atlanta, GA
Posts: 881
Received 79 Likes on 59 Posts
I did this as part of my battery/fuse relocation project:

Battery -> Circuit Relay -> 30A Inline fuse -> Fuel pump
Old 06-20-09, 02:27 AM
  #4  
Talk to me....

iTrader: (2)
 
Uncle Hungry's Avatar
 
Join Date: Sep 2007
Location: 600' up
Posts: 1,057
Received 51 Likes on 35 Posts
Why 30A? I just used the stock 20A.
Old 06-20-09, 07:25 AM
  #5  
It's finally reliable

iTrader: (18)
 
MOBEONER's Avatar
 
Join Date: May 2004
Location: NEW YORK CITY
Posts: 3,511
Received 9 Likes on 7 Posts
Does any one have a diagram of where it ties in (fuel pump)?
dale`s web site is not up and i seem not to find that fuel pump write up.
Old 06-20-09, 08:11 AM
  #6  
Constant threat

 
bajaman's Avatar
 
Join Date: Jul 2001
Location: near Wichita, Kansas
Posts: 4,952
Received 35 Likes on 31 Posts
Originally Posted by NeoTuri
I did this as part of my battery/fuse relocation project:

Battery -> Circuit Relay -> 30A Inline fuse -> Fuel pump
Yeah, I mean...JEBUS! 30 amps!
Old 06-20-09, 11:18 AM
  #7  
needs more track time

iTrader: (16)
 
gracer7-rx7's Avatar
 
Join Date: Mar 2006
Location: Bay Area CA
Posts: 9,182
Received 507 Likes on 349 Posts
Any write ups on how to do this?

Do you remove the factory wiring or do you add wiring in parallel?
Old 06-20-09, 11:35 AM
  #8  
Goodfalla Engine Complete

iTrader: (28)
 
Monkman33's Avatar
 
Join Date: May 2005
Location: Kennewick, Washington
Posts: 3,233
Received 32 Likes on 25 Posts
The fuse should be ran for the wire size, so if he ran a 10 gauge wire, then a 30 amp fuse is fine. The fuse is only to protect the wire.
Old 06-20-09, 01:55 PM
  #9  
Talk to me....

iTrader: (2)
 
Uncle Hungry's Avatar
 
Join Date: Sep 2007
Location: 600' up
Posts: 1,057
Received 51 Likes on 35 Posts
I gotcha, I didn't run new wires I just changed the source.
Old 06-20-09, 03:12 PM
  #10  
wannaspeed.com

iTrader: (23)
 
Dudemaaanownsanrx7's Avatar
 
Join Date: Feb 2003
Location: Texas
Posts: 2,802
Likes: 0
Received 5 Likes on 5 Posts
Name:  Fuelpumprewire-1.jpg
Views: 15999
Size:  51.1 KB
The following users liked this post:
Tristan Morales (03-06-19)
Old 06-20-09, 03:25 PM
  #11  
It's finally reliable

iTrader: (18)
 
MOBEONER's Avatar
 
Join Date: May 2004
Location: NEW YORK CITY
Posts: 3,511
Received 9 Likes on 7 Posts
ok so.from battery run 10g wire with 20v fuse in between to #30 on the relay.Then cut the stock supply line to the fuel pump and run 10g wire from #87 relay to stock wire pump side.then run 10g wire from #86 relay to the car side of the stock supply line. is this correct?

and this bosh relay can be found by the fuel pump under the fuel pump cover is this correct?
Old 06-20-09, 03:36 PM
  #12  
Rotary Enthusiast

iTrader: (4)
 
DriftDreamzSS's Avatar
 
Join Date: Apr 2006
Location: Ventura
Posts: 1,236
Likes: 0
Received 3 Likes on 3 Posts
Is a full rewire really necessary? Ive only done the simple one DaleClark posted up. Has anyone actually ever had that setup perform poorly? Seems like alot of work if there is already a proven simple solution.
Old 06-20-09, 05:10 PM
  #13  
Polishing Fiend

iTrader: (139)
 
CrispyRX7's Avatar
 
Join Date: Apr 2001
Location: MD
Posts: 3,393
Received 42 Likes on 22 Posts
FWIW
http://www.reganrotaryracing.com/fddualfuelpumps.htm

Regards,
Crispy
The following users liked this post:
gracer7-rx7 (12-04-19)
Old 06-20-09, 05:51 PM
  #14  
Rotary Freak

 
mad_7tist's Avatar
 
Join Date: Jan 2004
Location: tampa
Posts: 1,899
Likes: 0
Received 0 Likes on 0 Posts
The other nice thing about rewiring the pump is that say you are using the standard wiring system, and the car is running/tuned well. If the speed relay or the ecu driver for the speed relay fails you will have no way of knowing. The pressure will fall, you could lean out and boom.
Old 06-20-09, 06:29 PM
  #15  
wannaspeed.com

iTrader: (23)
 
Dudemaaanownsanrx7's Avatar
 
Join Date: Feb 2003
Location: Texas
Posts: 2,802
Likes: 0
Received 5 Likes on 5 Posts
The bosch relay has to be purchased. I prefer to run a new wire especially since i'm running dual pumps. This bypasses all factory wire and connections so you know it's the best it can be, but either method works.
Old 06-20-09, 06:33 PM
  #16  
It's finally reliable

iTrader: (18)
 
MOBEONER's Avatar
 
Join Date: May 2004
Location: NEW YORK CITY
Posts: 3,511
Received 9 Likes on 7 Posts
where is a good source to purchase this bosh relay and is there a specific one?
Old 06-20-09, 07:24 PM
  #17  
Talk to me....

iTrader: (2)
 
Uncle Hungry's Avatar
 
Join Date: Sep 2007
Location: 600' up
Posts: 1,057
Received 51 Likes on 35 Posts
Any place that does car audio and alarms should carry them.
Old 06-20-09, 08:13 PM
  #18  
wannaspeed.com

iTrader: (23)
 
Dudemaaanownsanrx7's Avatar
 
Join Date: Feb 2003
Location: Texas
Posts: 2,802
Likes: 0
Received 5 Likes on 5 Posts
it doesn't have to be a bosch relay any 4 or 5 prong relay will work. Just make sure the red/wht wire goes to one of the coil side's of the relay, and ground goes to the other. This will make sure the relay is activated the same as the stock fuel pump is. Then the switched portion of the wire goes between the battery 12v+ and fuel pump. It's really simple.

If you want to go all out you can run a new wire off the pump and connect it to the relay instead of using the other side of the red/wht wire that was cut. Here's how I ran my wire.



Old 06-20-09, 08:26 PM
  #19  
Lives on the Forum

iTrader: (8)
 
thewird's Avatar
 
Join Date: Oct 2006
Location: Toronto, Canada
Posts: 6,591
Likes: 0
Received 11 Likes on 11 Posts
I have also rewired my fuel pump the way Dudemaaanownsanrx7 has shown. Fixed all my fuel problems I was having before. Dudemaaanownsanrx7, how did you seal those power lines going intank? I just used a rubber grommet like the one you have and used a bunch of slow drying epoxy.

thewird
Old 06-20-09, 08:36 PM
  #20  
Polishing Fiend

iTrader: (139)
 
CrispyRX7's Avatar
 
Join Date: Apr 2001
Location: MD
Posts: 3,393
Received 42 Likes on 22 Posts
Originally Posted by thewird
I have also rewired my fuel pump the way Dudemaaanownsanrx7 has shown. Fixed all my fuel problems I was having before. Dudemaaanownsanrx7, how did you seal those power lines going intank? I just used a rubber grommet like the one you have and used a bunch of slow drying epoxy.

thewird
Your guys need to watch those wiring penetrations in the fuel pump cover. Those little rubber grommets will wear over time and the last thing you want is a short to the cover with fuel vapors right there = kablammo

Crispy
Old 06-20-09, 09:21 PM
  #21  
wannaspeed.com

iTrader: (23)
 
Dudemaaanownsanrx7's Avatar
 
Join Date: Feb 2003
Location: Texas
Posts: 2,802
Likes: 0
Received 5 Likes on 5 Posts
I used fuel safe sealant to seal both sides of the grommets in. it's not shown in the picture. I don't see any possible way for my grommets to wear, they are sealed in and don't have any movement. I'm not worried about them, I do good work.
Old 06-20-09, 10:00 PM
  #22  
Polishing Fiend

iTrader: (139)
 
CrispyRX7's Avatar
 
Join Date: Apr 2001
Location: MD
Posts: 3,393
Received 42 Likes on 22 Posts
Originally Posted by Dudemaaanownsanrx7
I do good work.
I have no doubt you do.

Regards,
Crispy
Old 06-20-09, 10:16 PM
  #23  
wannaspeed.com

iTrader: (23)
 
Dudemaaanownsanrx7's Avatar
 
Join Date: Feb 2003
Location: Texas
Posts: 2,802
Likes: 0
Received 5 Likes on 5 Posts
lol thanks
Old 06-21-09, 01:00 AM
  #24  
F yo couch!

iTrader: (6)
 
helghast7's Avatar
 
Join Date: Feb 2007
Location: Belleville, NJ
Posts: 2,321
Likes: 0
Received 0 Likes on 0 Posts
ugh more stuff to do lol, keep it coming, the more i learn the longer my engine will last lol

my list of "to do's" keeps growing and growing
Old 06-21-09, 07:05 AM
  #25  
CURVE OF CONSTANT WIDTH

iTrader: (4)
 
RotaryBuddha's Avatar
 
Join Date: Mar 2004
Location: Wesley Chapel, FL
Posts: 2,314
Likes: 0
Received 1 Like on 1 Post
Don't forget about jumping out the resistor pack. If you don't the system could still send low voltage to the relay and it won't be able to pull in.


Quick Reply: why everyone should rewire their fuel pump



All times are GMT -5. The time now is 01:06 AM.