RX7Club.com - Mazda RX7 Forum

RX7Club.com - Mazda RX7 Forum (https://www.rx7club.com/)
-   2nd Generation Specific (1986-1992) (https://www.rx7club.com/2nd-generation-specific-1986-1992-17/)
-   -   Heater fan only works on MAX (https://www.rx7club.com/2nd-generation-specific-1986-1992-17/heater-fan-only-works-max-453079/)

ksiver 08-13-05 08:57 AM

Heater fan only works on MAX
 
My heater fan only worls on MAX.
When I move the slider from OFF up to Max I have a click when I move from OFF and when I am reach MAX and the same when I slides back to OFF.

The air mixer and temp mixer works as normal.

Thanks :)

firestarter810 08-13-05 09:21 AM

my blower quit working altogether...

I don't know if our cars have a blower motor modulator, but that's what your car sounds like it needs...

Check for power out of the modulator... You obviously have power when its on high...check at other speeds...if not, then its your modulator. If you do have power there...I have no idea

I have to look up the wiring diagram and see if its my modulator or my motor.

lastphaseofthis 08-13-05 09:45 AM

have the same problem, have to replace the 200 doller logicon unit found on mazdatrix, not worth it to mee... just enjoy max ac :)

2713ddddavid 08-13-05 12:30 PM

Check out Icemark`s site. He rebuilds logicons, wiper switches etc. I purchased a logicon, wiper switch and clock warning panel from him couple of months ago and they work perfect. The logicon was $75 i believe, check out the site.... good shit!!!!!!!

http://www.mazdamark.com/

:D

ksiver 08-14-05 07:19 AM

Thanks, I will contact IceMark and see what we do :)

Icemark 08-23-05 10:52 AM

sounds like a bad controller board in the Logicon if the blower is only working on max.

Yes I do have rebuilt controller boards as well as whole Logicons available or can rebuild your unit for you.

My webstore/site: www.mazdamark.com


All times are GMT -5. The time now is 11:51 PM.