Should the rear roter trailing coil be firing if the car isnt actually started up. I tested all my wires and the rear trailing coil isnt sparking while the car is cranking. I cant start the car so I was wondering if maybe this is just part of the way it starts, and that it would start firing as soon as the car was running.

Im just trying to rule out any possibilities.


Also has anyone had a problem with their premix setteling out of their gastank? Cause my car has sat for two months and im worried part of the reason it wont start is cause its just sucking up the settled out premix oil from the tank.
Old 03-21-04, 10:04 PM
  #2  
Rotary Freak

 
mad_7tist's Avatar
 
Join Date: Jan 2004
Location: tampa
Posts: 1,899
Likes: 0
Received 0 Likes on 0 Posts
they all fire during start-up. it will run without the trailing plugs at all
Old 03-21-04, 11:21 PM
  #3  
Ee / Cpe

Thread Starter
 
XSTransAm's Avatar
 
Join Date: Jan 2003
Location: Gaithersburg, MD / WVU
Posts: 2,843
Likes: 0
Received 2 Likes on 2 Posts
dammit :/

and the premix?
Old 03-21-04, 11:49 PM
  #4  
Slower Traffic Keep Right

iTrader: (5)
 
poss's Avatar
 
Join Date: Apr 2002
Location: Albuquerque, NM
Posts: 2,192
Received 2 Likes on 2 Posts
If you are worried about the pre-mix settling out, Just run your fuel pump for a little bit by putting a jumper from the F/P (?) to the nearest GND connection in the diagnosis box. I would think that that would mix the gas well enough.
Old 03-22-04, 12:03 AM
  #5  
I Sold My Car 2 the Devil

 
wonder1and's Avatar
 
Join Date: Oct 2001
Location: Duncanville, Tx
Posts: 2,361
Likes: 0
Received 0 Likes on 0 Posts
pull your egt bus fuse and give her some cranks... then plug back in to see if you were flooded... thats 10-15 sec. of cranks.
Old 03-22-04, 11:55 AM
  #6  
Tenseiga

iTrader: (1)
 
Sesshoumaru's Avatar
 
Join Date: Apr 2003
Location: Iowa
Posts: 2,252
Likes: 0
Received 0 Likes on 0 Posts
premix won't seperate after 2 mo - not sure if it ever does.

spark plugs will cause a problem of not firing too. An easy way to check to see if all your plugs are firing just hook a timing light up to them. It will flash if they are working.

Trailing are used to completey ignite all fuel (emission/ecconomy). They can run without.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
befarrer
Adaptronic Engine Mgmt - AUS
15
05-19-22 10:44 PM
vish86
Interior / Exterior / Audio
3
10-01-15 11:53 PM
Auroraw0lf
New Member RX-7 Technical
5
09-15-15 04:55 PM
msilvia
3rd Generation Specific (1993-2002)
15
09-11-15 12:13 PM



Quick Reply: A Stupid question...



All times are GMT -5. The time now is 04:44 PM.